R410a Series (Air-to-Water) Heat Pump
Specification \ Model
|
FHP-5A4A
|
FHP-8A4A
|
FHP-10A4A
|
FHP-12A4A
|
FHP-15A4A
|
FHP-15A4B
|
FHP-20A4B
|
FHP-25A4B
|
FHP-30A4B
|
FHP-35A4D
|
FHP-40A4B
|
FHP-50A4B
|
FHP-60A4B
|
Power
|
3φ220/380/440V 60 Hz
|
Heating capacity
|
KW
|
17.5
|
27
|
36
|
43
|
52
|
54
|
72
|
85
|
104
|
124
|
144
|
171
|
209
|
Size
|
H
|
mm
|
1390
|
1790
|
1870
|
1870
|
2040
|
2040
|
2040
|
2040
|
2040
|
2140
|
2140
|
2250
|
2250
|
W
|
mm
|
1020
|
1465
|
1465
|
1465
|
2005
|
2005
|
2005
|
2005
|
2005
|
2928
|
2928
|
2100
|
2100
|
D
|
mm
|
370
|
947
|
950
|
950
|
1050
|
1050
|
1050
|
1050
|
1050
|
1050
|
1050
|
2000
|
2000
|
Running current
|
A
|
20.3/11.8/10.2
|
29.7/82.9/71.6
|
36.6/21.2/18.3
|
41.9/24.3/21.0
|
54.5/31.6/27.3
|
55.5/32.1/27.8
|
71.6/41.5/35.8
|
88.9/51.5/44.5
|
113.0/65.4/56.5
|
137.2/79.4/68.6
|
143.7/83.2/71.9
|
152/88/76
|
200/115.8/100
|
Power consume
|
KW
|
5.46
|
8.28
|
10.73
|
12.83
|
16.86
|
16.58
|
21.46
|
25.66
|
33.72
|
38.82
|
42.92
|
51.32
|
67.44
|
COP
|
W/W
|
3.19
|
3.26
|
3.37
|
3.33
|
3.10
|
3.26
|
3.37
|
3.33
|
3.10
|
3.20
|
3.37
|
3.33
|
3.10
|
Compressor
|
Type
|
Hermetic-scroll
|
Quantity
|
1
|
1
|
1
|
1
|
1
|
2
|
2
|
2
|
2
|
2
|
4
|
4
|
4
|
Capacity adjustment(%)
|
100,0%
|
100,50,0%
|
Start-up
|
Sequential
|
Sequential
|
Evaporator
|
Type
|
Fin and Tube type
|
Type of Fan
|
Propeller type
|
Motor power W
|
104X2
|
390
|
243
|
243
|
390
|
390
|
390
|
450
|
770
|
770
|
380
|
450
|
770
|
Number of fan and motor
|
2
|
1
|
2
|
2
|
2
|
2
|
2
|
2
|
2
|
2
|
4
|
4
|
4
|
Wind direction
|
Front-Side
|
Top-Side
|
Heater
|
Type
|
Flat/ shell tube exchanger
|
Water Flow L/min
|
48
|
78
|
102
|
122
|
150
|
150
|
207
|
245
|
298
|
355
|
413
|
490
|
599
|
Pipe diameter
|
PT 1 B
|
PT 1 ½ B
|
PT 1 ½ B
|
PT 2 B
|
PT 2 B
|
PT 2 B
|
PT 2 B
|
PT 2 ½ B
|
PT 2 ½ B
|
PT 2 ½ B
|
PT 2 ½ B
|
PT 3 B
|
PT 3 B
|
Internal water pump head (M)
|
24
|
23
|
22
|
20
|
18
|
18
|
22
|
19
|
22
|
21
|
20
|
19
|
21
|
Device Protection
|
High & low pressure switch、defrost protection、fan motor over heat protection 、phase reverse relay、 compressor over load protection、safety valve、pump over load protection
|
Refrigerant
|
R140a
|
Weight
|
kg
|
145
|
320
|
340
|
385
|
460
|
495
|
510
|
600
|
685
|
890
|
1250
|
1320
|
1470
|
Note: 1. Heat generation testing standard: heat water from 45℃ to 50℃. The environment is 20℃ DB, 15℃ WB.
2. Suggest the hot water outlet under 57℃.
3. Water pump is excluded in Power consumption and COP calculation. Please contact with the business division for any special manufacture requirement
4. Efficiency unit is 1KW = 860 Kcal/hr
|